Wiring white rodgers zone valves

Wiring white rodgers zone valves


Hi I have a new weil mclain cga-4 standing pilot boiler and 2 white rodgers 1311-102 zone valves. How do i wire the zone valves to the boiler? The boiler has 2 wires coming from the transformer relay R and G terminals marked 24 v thermostat. Is this where i wire the wires from the zone valves? If you have a diagram it would be most helpful. Thanks. Scott Hi Scott, do you already have the zone valves wired up? I think you know that those valves need a particular 3 wire thermostat, correct? ( curious why you chose those? ) I would have used the 1361 series so as to be able to use off the shelf 2 wire thermostats... Here's the PDF for your zone valves, Figure 9 comes closest to what you need... of course you only have two valves so ignore the 'extras'. Where that diagram shows connections to T1 and T2 on the boiler control, you will use the R and G on your boiler. On your valves, terminals 2 and 5 are connected internally. You will wire terminal 3 and (2 OR 5) to the G and R on your boiler. Questions? Thanks for replying NJ Trooper. I have deceided to replace the white rodgers valves since they are 30 years old and install Taco Zone Sentry Zone valves instead. I looked at the wiring diagram and i think i know install them. Have you heard much about these valves? Any good? Scott Sorry, I know as much about them as you do! I've read all the literature and stuff... I like the idea of an actual 'ball valve' as the operator... but hands on experience with them? zip... I haven't heard anything BAD about them though, and that's GOOD!


Related Posts:




  • Wiring zone valves

    wiring zone valvesHi: Have replaced old cast iron with pex. Kept cast iron radiators (hot water) on first floor. Second floor used fin and tube. Created 2 zones. Original thermostat is two wire, h...


  • White rodgers zone valve wiring

    White Rodgers zone valve wiringI'm replacing a basic round Honeywell HEATING ONLY t'stat (without any switches) for a hot water system with a programmable digital to save energy. The White Rogers...


  • Taco zone valve wiring

    Taco zone valve wiringFirst post, new to the forums. Im trying to add two Taco 571 zone valves to my baseboard hot water system. My set up is this: a Slant/fin Sentry 105K BTU gas fired furnace wi...


  • Wiring an electric water heater

    Wiring an Electric Water heaterFirst of all I didn't wire the heater the first time, but I am fairly sure that is was wired incorrectly at least in part. It is a whirlpool 40 gallon 2 element unit...


  • Tac thermostat model 31100 for normallyopen zone valve

    TAC thermostat (model 31-100) for Normally-open zone valveMy condo has a central boiler on top of the 12-storey building that feeds hot water to baseboard heater in each unit. There is a room ther...