Honeywell Thermostat setting,,,,,,,
I am trying to set the heat anticipater' on my wall mounted furnace thermostat. The furnace starts ok but it seems to run a bit longer than I feel in right. The rooms heat up well before the thermostat decides to shut the furnace off. Not horribly long but longer than I'd like. I looked at the setting on my anticipater and it is set at .15. Should I set it higher, like maybe towards .18, or should I take it the other direction, like maybe .13? I'm not sure which way to go, or how much. Thanks,,,, As a basic procedure: Adjust the heat-anticipator lever one calibration mark closer to the LONGER setting if the furnace turns off and on too frequently. If the furnace allows room temperature to fall too low or rise too high before going off, move the lever one mark away from the LONGER setting. I normaly set it at .8 the 1.2 is the longest run time and going down to the right to .2 is the shortest run time. You don't want to short cycle, it's harder on the equipment. pear, The correct way to set the heat anticipator is to match it to the milliamp draw of the gas valve. Most gas valves have a plate on them with information like model number, type, max pressure and the “amp” draw. Sometimes the information is stamped into the gas valve itself and sometimes there’s no info at all. At that point, if you can't find the info on a plate or on the valve, you would need to measure the amp draw with a clamp on ammeter. But remember you’re looking at milliamps; so with a clamp on meter you would use 10 turns of wire around the pick up, read the current and then divide that number by 10. Basically, you set the heat anticipator to match the amp draw of the gas valve. So if you read on the plate the amp draw to be .4 amps; you would set the heat anticipator to .4 Some HVAC techs will set the anticipator one amp more than the gas valve milliamp draw to give a little longer run time and a longer off time. Phil
Related Posts:
Honeywell thermostat t8000c issue
Honeywell Thermostat T8000C IssueMy wife and I are new house owners, and this is the first time I really had an issue that I need to solve for thermostats A/C. Here's the issue: Currently, the the...
Honeywell locked thermostat
Honeywell locked thermostatHi, we have a locked thermostat and cannot unlock it. Anyone familiar with this: Ultrastat...it has 3 buttons on the bottom of face plate/ System and Fan/ Override/ More...
Honeywell r8182d high limit
Honeywell R8182D High LimitI have a Burnham furnace with a Beckett burner, 3 heating zones and a tankless coil. According to the Honeywell manual, when a thermostat calls for heat, both the circul...
Honeywell l8148a aquastat relay and carrier boiler
Honeywell L8148A, Aquastat Relay and Carrier BoilerHi, My first post......pardon me as I try this.... I have a Carrier Hot Water gas fired boiler with a Honeywell L8148A, Aquastat. The house has 4...
Installing honeywell rth6500wf wifi thermostat c wire question
Installing Honeywell RTH6500WF Wifi Thermostat c wire questionHi, I'm trying to replace an old mercury switch 4 wire thermostat with a new wifi Honeywell rth6500wf. I do not have a c wire. I do no...